실외 고정형 LED 디스플레이 · 제품 시리즈

Outdoor fixed LED, IP65 brightness for direct sun.

P2.6 · P3.9 · P4 · P4.8 · P5 · P6.25 · P6.67 · P10

파사드와 가로 광고를 위한 IP65 공통 캐소드 캐비닛. 높은 밝기가 직사광선에서 작동하며 밀폐 구조와 열 설계가 비, 먼지, 온도 변화를 견딥니다.

5,500–13,000 nits

Brightness for sunlit walls

IP65

Sealed front and rear for rain and dust

Common cathode

Lower heat and running cost

실외 고정형 LED 디스플레이 cabinet
실외 고정형 LED 디스플레이 · factory cabinet and module build

모델

1m Profile Cabinet

1000 × 1000 × 90mm · 500 × 250mm module · 27.72kg

The fixed-series outdoor platform: a CNC-machined aluminium profile cabinet, 500 × 250mm aluminium-base module, common-cathode drive and front or rear service.

Outdoor P2.6 cabinet

Outdoor P2.6

2.97mm
밝기
≥7,000 cd/m²
평균 소비전력
180 W/m²
캐비닛 크기
1000×1000×90mm
View product details
Outdoor P3.9 cabinet

Outdoor P3.9

3.91mm
밝기
≥7,000 cd/m²
평균 소비전력
180 W/m²
캐비닛 크기
1000×1000×90mm
View product details
Outdoor P4.8 cabinet

Outdoor P4.8

4.81mm
밝기
≥7,000 cd/m²
평균 소비전력
180 W/m²
캐비닛 크기
1000×1000×90mm
View product details
Outdoor P6.25 cabinet

Outdoor P6.25

6.25mm
밝기
≥8,000 cd/m²
평균 소비전력
180 W/m²
캐비닛 크기
1000×1000×90mm
View product details

960 × 960 Cabinet

960 × 960 × 88.5mm · 480 × 320mm module · 21kg · 6,000–12,000 nits

The 960 × 960mm aluminium cabinet platform shared by P4, P5, P8 and P10. P4, P5 and P8 use eight 480 × 320mm modules in a 2 × 4 layout; P10 uses six modules in a 2 × 3 layout, with stainless-steel quick locks and front or rear access.

Outdoor P4 cabinet

Outdoor P4

4mm
밝기
6,000–12,000 nits
평균 소비전력
200–300 W/m²
캐비닛 크기
960×960×88.5mm
View product details
Outdoor P5 cabinet

Outdoor P5

5mm
밝기
6,000–12,000 nits
평균 소비전력
100–200 W/m²
캐비닛 크기
960×960×88.5mm
View product details
Outdoor P8 cabinet

Outdoor P8

8mm
밝기
6,000–12,000 nits
평균 소비전력
100–200 W/m²
캐비닛 크기
960×960×88.5mm
View product details
Outdoor P10 cabinet

Outdoor P10

10mm
밝기
6,000–12,000 nits
평균 소비전력
100–200 W/m²
캐비닛 크기
960×960×88.5mm
View product details

960mm Standard Cabinet

960 × 960mm · large-format outdoor cabinet

A 960 × 960mm outdoor cabinet retained for long-throw and replacement projects where the existing structure and cabinet count are already fixed.

Outdoor P6.67 cabinet

Outdoor P6.67

6.67mm
밝기
5,500–13,000 nits
평균 소비전력
≤300 W/m²
캐비닛 크기
960×960mm
View product details

장점

IP65 캐비닛

비와 먼지에 대해 전면과 후면을 밀폐.

5,500–13,000 nit

직사광선에서도 가독성.

공통 캐소드

일반 드라이버보다 낮은 소비전력과 발열.

내식성

해안과 습한 지역을 위한 코팅.

실외 고정형 LED 디스플레이

Structure introduction

outdoor fixed LED display is built around a sealed 1000 × 1000 × 90 / 960 × 960 × 88.5mm cabinet. The front module, gasket, rear cover and pressure path are designed as one weather system, so rain, dust and thermal expansion do not open a path into the electronics.

Series specification
01

IP65 sealed enclosure

A continuous gasket runs around the module and rear cover. Cable entries use sealed glands, and the cabinet is tested before packing.

02

Module and heat sink

The LED module sits against a thermal path that spreads heat across the cabinet back. The heat sink is isolated from the sealed electronics chamber.

03

Power and control chamber

Power supplies and receiving cards are mounted in a protected chamber with a separate service cover, keeping water away from live connections.

04

Mounting and wind load

Mounting points are sized for the cabinet weight and site wind load. The structure is confirmed against the installation height before production.

Design details

The decisions that affect how 실외 고정형 LED 디스플레이 looks, installs and stays serviceable on site.

01

Water path, not just a gasket

The cabinet is shaped so water runs away from the module seam. Service covers overlap the opening rather than sitting flush, which is what keeps a facade dry in driving rain.

02

Daylight brightness

5,500–13,000 nits output is paired with automatic brightness control, so the wall stays readable at noon without glare at night.

03

Thermal expansion

Module and cabinet materials are selected to expand together. The module fixing allows controlled movement instead of stressing the LED board.

04

Anti-corrosion finish

Cabinet surfaces are coated for humid and coastal sites. Fixings and grounding points are specified for long-term outdoor service.

Front maintenance

Service is planned before the wall is built. Modules, cards and power supplies are replaced from the access direction agreed on the drawing.

Front-service module design

Front service from the walkway

Modules can be released from the front where the wall faces a road or facade with no rear access. The service procedure keeps the gasket path intact.

Rear access for power and control

Where a rear walkway exists, power supplies and receiving cards are reached through a separate sealed cover without opening the module face.

Gasket and drainage checks

Service visits include a gasket inspection and drainage check. Replacement modules are supplied with the correct seal kit for the cabinet revision.

Product credibility

Documented before it ships

실외 고정형 LED 디스플레이 is built on the same production line as our project walls. Cabinets, modules and control settings are recorded per batch, and the documentation travels with the shipment so the site team is not working from memory.

ISO 9001

Factory process control

CE / RoHS / FCC

Product compliance

Batch tested

Aging and calibration record

2–3 years

Standard warranty

Quality record

  • CE, RoHS and FCC documentation for the supplied configuration.
  • Aging and white-balance calibration record per batch.
  • Cabinet drawing, pixel map and control settings in the handover pack.
  • Spare modules matched to the original production batch.

적용 분야

건물 파사드

도시에서 보이는 대형 미디어 월.

가로 빌보드

장거리 시청을 위한 고휘도.

경기장 둘레

햇빛과 비에도 안정적인 화면.

교통 허브

내구성 높은 정보·광고 벽면.

Outdoor fixed selection and delivery

Outdoor selection starts with the weather path

Brightness is only one part of an outdoor specification. Water paths, wind load, thermal expansion and service access determine whether the wall still performs after the first rainy season.

01P2.6–P10

Set brightness from the viewing direction

P2.6–P4.8 for close street viewing and building entrances; P6.67–P10 for roadside, facade and stadium distances where the nearest viewer is beyond 10 m.

02IP65 front and rear

Trace the water path

IP65 depends on gasket continuity, cable glands and cover overlap, not on a single rating label. The cabinet should shed water away from the module seam and service openings.

03Wind-load review

Confirm structure and service

Mounting points, wind load and the service route are reviewed against the installation height. Front service is used where the wall faces a road or facade with no rear walkway.

Deployment playbook

Outdoor walls where the site sets the build

A roadside billboard, a building facade and a stadium perimeter use different cabinet formats, brightness levels and service strategies.

01

Roadside and street media

The wall must stay readable in direct sun and dim at night. Automatic brightness control, high output and a sealed enclosure are the base requirements.

P4–P8 · 5,500–13,000 nits · auto dimming

02

Building facades

Wind load and fixing detail dominate. The cabinet and support frame are reviewed together, with service access planned from the facade or a maintenance walkway.

P6.67–P10 · IP65 · wind-load frame

03

Stadium perimeter

The wall is close to the pitch and on broadcast cameras. High refresh, fast-lock cabinets and a service plan for match days are part of the specification.

P4.81–P6.67 · >7680Hz · fast service

Delivery control

Outdoor build and weather test

Outdoor cabinets are assembled and sealed before packing. The factory check covers gasket continuity, cable entry and the service covers that are most likely to be opened on site.

Handover pack

  • Approved cabinet layout and pixel map
  • Control settings and calibration record
  • Packing list, spare list and service notes
Request the current datasheet
  1. 1

    Freeze the drawing

    Approved layout, pixel map and power schedule

    Cabinet layout, control points, power distribution and the service direction are fixed before materials are cut. The approved drawing becomes the reference for every later check.

  2. 2

    Match the batch

    Batch record and module position list

    LED modules, driver ICs and power supplies are drawn from the same production batch where the order size allows, then labelled by cabinet position.

  3. 3

    Age and calibrate

    Aging log and calibration file

    Assembled cabinets run through an aging cycle and white-balance calibration. Faults found at this stage are corrected before packing, not after arrival.

  4. 4

    Pack for the route

    Packing list, spare list and handover pack

    Cabinets are packed against the transport method and site access. The packing list includes the seal kit, service gaskets and the fixing schedule for the approved structure.

Buyer questions

Questions we answer before quotation

These are the points that most often change the specification after the first enquiry. If your question is not here, send it with the site details.

Ask an engineer
01Is IP65 enough for coastal installations?

IP65 is the starting point, but coastal sites also need corrosion protection, suitable fixings and a maintenance schedule. The cabinet finish and grounding detail are confirmed against the site conditions.

02How is wind load handled?

The mounting points and support structure are reviewed against the installation height, exposure and local requirements. The display cabinet is not specified in isolation from its frame.

03Can the wall be serviced from the front?

Yes, front-service modules are available for walls with no rear access. Where a rear walkway exists, power supplies and receiving cards can be reached through a separate sealed cover.

04What brightness is recommended for a roadside wall?

Outdoor walls can be configured from 5,500 to 13,000 nits with automatic dimming. The final setting depends on orientation, viewing distance and local brightness rules.

실외 화면 주문

설치 높이와 시청 거리를 알려주세요. 피치, 밝기, 구조를 확인해 드립니다.